Home » Product List » Indian Emission Standard Silent Series Diesel Generator Set » Indian Emission Standard Silent Series Diesel Generator Sets
Product Details
Indian Emission Standard Silent Series Diesel Generator Sets
RELIANLE PERFRMANCE
1. Noise grade limit(1m away from the set): 75dB;
2. Steady voltage regulation rate: ≤ ± 1%;
3. Transient state voltage regulation rate: ≤ -10%~+15%;
4. Steady state voltage regulation rate: ≤ 5%;
5. Transient state frequency regulation rate: ≤ ± 10%
6. No-load voltage setting range: ≥ (95-105)%;
STRUCTURE
1. The generator set features in small volume, light weight and compact structure.
2. The acoustic shield is nice-looking and is convenient to be removed or installed, The set is draughty insede.
3. There are doors on both sides that it makes adding fuel or oil more convenient.
4. The control panel is well designed, The set is easy to control and operates safely. Its Performance is really reliable.
Note: 1. The modification of the product appearance or technical parameters, Which is a result of technique improvement, will not be announced additionally.
2. According to different user's different requirements, we can offer various configures of generator set.
| Type | BFS-10 | BFS-12 | BFS-15 | BFS-18 | BFS-20 | BFS-25 | BFS-30 | BFS-40 | BFS-50 | BFS-60 | BFS-70 | BFS-80 | BFS-90 | BFS-100 | |
| Rated Power(KW)/(KVA) | 10/12.5 | 12/13.2 | 15/16.5 | 18/19.8 | 20/22 | 25/27.5 | 30/33 | 40/44 | 50/55 | 60/66 | 70/77 | 80/88 | 90/99 | 100/110 | |
| Rated Voltage(V) | 400/230 | ||||||||||||||
| Rated Current(A) | 18 | 21.6 | 27 | 32.4 | 36 | 45 | 54 | 72 | 90.2 | 108 | 126 | 144 | 162 | 180.4 | |
| Rated Frequency(HZ) | 50/60 | ||||||||||||||
| Rated Revolving Speed(r/min) | 1500/1800 | ||||||||||||||
| Rated Power Factor | 0.8LAG | ||||||||||||||
| Phases Arrangement | 3P4W | ||||||||||||||
| Diesel Engine | Type | BR2100D | BR2108D | BR3105D | BR3105D | BR3108D | BR4105D | BR4108D | BR4105ZD | BR4105ZD | BR4105ZLD | BR6105ZD | BR6105ZLD | BR6105ZLD | BR6105ZLD |
| 12h power/standby power(KW) | 14/15.4 | 18.6/20.46 | 25.6/28.16 | 25.6/28.16 | 27.5/3025 | 34.2/37.62 | 37/40.7 | 59.5/65.45 | 59.5/65.45 | 75/82.5 | 90/99 | 132/145.2 | 132/145.2 | 132/145.2 | |
| Starting Mode | Electrical Starting DC12V | Electrical Starting DC24V | |||||||||||||
| Speed Regulation Mode | Mechanical/Electrical | ||||||||||||||
| Alternator | Type | XN164C | XN164D | XN184E | XN184E | XN184EF | XN184G | XN184H | XN224D | XN224E | XN224F | XN224G | XN274D | XN274D | XN274DS |
| Rated Power(KW)/(KVA) | 10 | 12 | 15 | 18 | 20 | 25 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | |
| Excitation Mode | Brushless Excitation With AVR | ||||||||||||||
| Insulation Class | H(Temperature rise limit:125k) | ||||||||||||||
| Protection Class | IP22 | ||||||||||||||
| Control Unit Type | Integral Type | ||||||||||||||
Inquiry Basket (